CLI Guide

Usage Information The polling interval for an interface is the maximum number of seconds between
successive samples of counters sent to the collector. This command changes the
global default counter polling (20 seconds) interval. You can configure an interface
to use a different polling interval.
sflow polling-interval (Interface)
Set the sFlow polling interval at an interface (overrides the global-level setting).
Syntax
sflow polling-interval interval value
To return to the default, use the no sflow polling-interval interval
command.
Parameters
interval value Enter the interval value in seconds. The range is from 15 to
86400 seconds. The default is the global counter polling
interval.
Defaults The same value as the current global default counter polling interval.
Command Modes INTERFACE
Supported Modes Full–Switch Mode
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information This command sets the counter polling interval for an interface.
Related
Commands
sflow polling-interval (Global) — globally sets the polling interval.
sflow sample-rate (Global)
Change the global default sampling rate.
Syntax
sflow sample-rate value
To return to the default sampling rate, use the no sflow sample-rate
command.
Parameters
value Enter the sampling rate value. The range is from 256 to
8388608 packets. Enter values in powers of 2 only; for
1382
sFlow