CLI Guide

Command Modes CONFIGURATION
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
rmon hc-alarm
Set an alarm on any MIB object.
Syntax
rmon hc-alarm number variable interval {delta | absolute}
rising-threshold value event-number falling-threshold value
event-number [owner string]
To disable the alarm, use the no rmon hc-alarm number command.
Parameters
number Enter the alarm integer number from 1 to 65535. The value
must be unique in the RMON alarm table.
variable The MIB object to monitor. The variable must be in the
SNMP OID format; for example, 1.3.6.1.2.1.1.3 The object
type must be a 64-bit integer.
interval Time, in seconds, the alarm monitors the MIB variables; this
is the alarmSampleType in the RMON alarm table. The range
is from 5 to 3600 seconds.
delta Enter the keyword delta to test the change between MIB
variables. This is the alarmSampleType in the RMON alarm
table.
absolute Enter the keyword absolute to test each MIB variable
directly. This is the alarmSampleType in the RMON alarm
table.
rising-threshold
value event-
number
Enter the keywords rising-threshold then the value (64
bit) the rising-threshold alarm is either triggered or reset.
Then enter the event-number to trigger when the rising
threshold exceeds its limit. This value is the same as the
alarmRisingEventIndex or alarmTable of the RMON MIB. If
there is no corresponding rising-threshold event, the value
is zero.
falling-threshold
value event-
number
Enter the keywords falling-threshold then the value
(64 bit) the falling-threshold alarm is either triggered or
reset. Then enter the event-number to trigger when the
falling threshold exceeds its limit. This value is the same as
1288
Remote Monitoring (RMON)