CLI Guide

stack-unit unit-id Enter the keywords stack-unit then the unit-id to display
information on a specific stack member. The range is from 0
to 5.
thermal sensor Enter the keywords thermal-sensor to view all
components.
Command Modes
EXEC
EXEC Privilege
Supported Modes All Modes
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
8.3.17.0 Supported on the M I/O Aggregator.
Example (all)
Dell#show environment all
-- Unit Environment Status --
Unit Status Temp Voltage TempStatus
--------------------------------------
* 1 online 66C ok 2
* Management Unit
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6
Sensor7
Sensor8 Sensor9
-----------------------------------------------------------------
1 51 51 63 61 61 61 67 61
64 66
Dell#
Example (stack-
unit)
Dell#show environment stack-unit
-- Unit Environment Status --
Unit Status Temp Voltage TempStatus
------------------------------------------
* 1 online 66C ok 2
* Management Unit
Dell#
Example (thermal-
sensor)
Dell#show environment thermal-sensor
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6
Sensor7
Sensor8 Sensor9
-----------------------------------------------------------------
1 51 51 64 61 61 61 67 61
64 66
Dell#
Control and Monitoring