CLI Guide

server-fabric connection over an FN I/O Aggregator with the FC Flex IO module
NPIV proxy gateway.
The following describes the show npiv devices brief output shown in the
example.
Field Description
ENode-Intf FN I/O Aggregator with the FC Flex IO module Ethernet
interface (slot/port) to which a server CNA is connected.
ENode-WWPN Worldwide port name (WWPN) of a server CNA port.
FCoE-Vlan VLAN ID of the dedicated VLAN used to transmit FCoE traffic
to and from the fabric.
Fabric-Intf Fabric-facing Fibre Channel port (slot/port) on which FC
traffic is transmitted to the specified fabric.
Fabric-Map Name of the FCoE map containing the FCoE/FC
configuration parameters for the server CNA-fabric
connection.
LoginMethod Method used by the server CNA to log in to the fabric; for
example:
FLOGI - ENode logged in using a fabric login (FLOGI).
FDISC - ENode logged in using a fabric discovery (FDISC).
Status Operational status of the link between a server CNA port
and a SAN fabric: Logged In - Server has logged in to the
fabric and is able to transmit FCoE traffic.
Example
Dell# show npiv devices brief
Total NPIV Devices = 2
---------------------------------------------------------
ENode-Intf ENode-WWPN FCoE-Vlan abric-Intf Fabric-Map LginMethod Status
---------------------------------------------------------------------
Te 0/12 20:01:00:10:18:f1:94:20 1003 Fc 0/5 fid_1003 FLOG LOGGED_IN
Te 0/13 10:00:00:00:c9:d9:9c:cb 1003 Fc 0/0 fid_1003 FDISC LOGGED_IN
Usage Information
The following describes the show npiv devices output shown in the example.
Field Description
ENode [number] A server CNA that has successfully logged in to a fabric over
an FN I/O Aggregator with the FC Flex IO module Ethernet
port in ENode mode.
Enode MAC MAC address of a server CNA port.
Enode Intf Port number of a server-facing Ethernet port operating in
ENode mode.
1050