CLI Guide
On an FN2210S Aggregator a with the PMUX module NPIV proxy gateway, you
cannot apply an FCoE map applied on fabric-facing FC ports and server-facing 10–
Gigabit Ethernet ports.
An FCoE map consists of the following parameters: the dedicated FCoE VLAN used
for storage traffic, the destination SAN fabric (FC-MAP value), FCF priority used by a
server, and the FIP keepalive (FKA) advertisement timeout.
In each FCoE map, the fabric ID, FC-MAP value, and FCoE VLAN parameters must
be unique. Use one FCoE map to access one SAN fabric. You cannot use the same
FCoE map to access different fabrics.
To remove an FCoE map from an Ethernet interface, enter the no fcoe-map
map-name command in Interface configuration mode.
Related
Commands
show fcoe-map— displays the Fibre Channel and FCoE configuration parameters in
FCoE maps.
feature fc
Enables the Fibre channel communication via the NPG functionality.
Syntax
feature fc
Command Modes CONFIGURATION
Supported Modes Programmable-Mux (PMUX)
Full–Switch
Default Enabled
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.6(0.0) Supported on the FN I/O Aggregator.
9.3(0.0) Supported on the M I/O Aaggregator.
Usage Information The command is supported only in FN2210S Aggregator.
fka-adv-period
In an FCoE map, configure the time interval used to transmit FIP keepalive (FKA) advertisements.
Syntax
fka-adv-period seconds
NPIV Proxy Gateway