CLI Guide

fcoe-map
Create an FCoE map which contains the parameters used to configure the links between server CNAs
and a SAN fabric. Apply the FCoE map on a server-facing Ethernet port.
Syntax
fcoe-map map-name
Parameters
map-name Maximum: 32 alphanumeric characters.
Defaults On the FN2210S Aggregator with PMUX modules, the following parameters are
applied on all the PMUX module interfaces:
Description: SAN_FABRIC
Fabric-id: 1002
Fcoe-vlan: 1002
Fc-map: 0x0efc00
Fcf-priority: 128
Fka-adv-period: 8000mSec
Keepalive: enable
Vlan priority: 3
Command Modes CONFIGURATION
INTERFACE
Supported Modes Programmable-Mux (PMUX)
Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.6(0.0) Supported on the FN2210S Aggregator with the PMUX
module.
9.3(0.0) Introduced on the M I/O Aggregator with the PMUX
module.
Usage Information
An FCoE map is a template used to map FCoE and FC parameters in a converged
fabric. An FCoE map is used to virtualize upstream FC ports on an FN2210S
Aggregator with the PMUX module NPIV proxy gateway so that they appear to
downstream server CNA ports as FCoE forwarder (FCF) ports on an FCoE network.
When applied to FC and Ethernet ports on an NPIV proxy gateway, an FCoE map
allows the switch to operate as an FCoE-FC bridge between an FC SAN and an
FCoE network by providing FCoE-enabled servers and switches with the necessary
parameters to log in to a SAN fabric.
1042
NPIV Proxy Gateway