CLI Guide
Enabling Portfast BPDU guard and loop guard at the same time on a port results in
a port that remains in a blocking state and prevents traffic from flowing through it.
For example, when Portfast BPDU guard and loop guard are both configured:
• If a BPDU is received from a remote device, BPDU guard places the port in an
err-disabled blocking state and no traffic is forwarded on the port.
• If no BPDU is received from a remote device, loop guard places the port in a
loop-inconsistent blocking state and no traffic is forwarded on the port.
tc-flush-standard
Enable the MAC address flushing after receiving every topology change notification.
Syntax
tc-flush-standard
To disable, use the no tc-flush-standard command.
Defaults Disabled.
Command Modes CONFIGURATION
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information By default, the sytem implements an optimized flush mechanism for MSTP. This
mechanism helps in flushing the MAC addresses only when necessary (and less
often) allowing for faster convergence during topology changes. However, if a
standards-based flush mechanism is needed, this knob command can be turned
on to enable flushing MAC addresses after receiving every topology change
notification.
Multiple Spanning Tree Protocol (MSTP)
1023