Administrator Guide
In the following example, port Te 0/40 in VLT peer 1 is connected to Te 0/48 of TOR and port Te 0/18 in VLT
peer 2 is connected to Te 0/50 of TOR.
1 Configure the static LAG/LACP between ports connected from VLT peer 1 and VLT peer 2 to the top of
rack unit.
2 Configure the VLT peer link port channel id in VLT peer 1 and VLT peer 2.
3 In the top of rack unit, configure LACP in the physical ports (shown for VLT peer 1 only. Repeat steps for
VLT peer 2. The highlighted vlt-peer-lag port-channel 2 indicates that port-channel 2 is the port-
channel id configured in VLT peer 2).
fniom-2#show running-config interface tengigabitethernet 0/40
!
interface TenGigabitEthernet 0/40
no ip address
!
port-channel-protocol LACP
port-channel 2 mode active
no shutdown
fniom-2#
configuring VLT peer lag in VLT
fniom-2#show running-config interface port-channel 2
!
interface Port-channel 2
no ip address
switchport
vlt-peer-lag port-channel 2
no shutdown
fniom-2#
fniom-2#show interfaces port-channel 2 brief
Codes: L - LACP Port-channel
LAG Mode Status Uptime Ports
L 2 L2L3 up 03:33:14 Te 0/40 (Up)
fniom-2#
fniom-4#show running-config interface tengigabitethernet 0/40
!
interface TenGigabitEthernet 0/40
no ip address
!
port-channel-protocol LACP
port-channel 2 mode active
no shutdown
fniom-4#
configuring VLT peer lag in VLT
fniom-4#show running-config interface port-channel 2
!
interface Port-channel 2
no ip address
switchport
vlt-peer-lag port-channel 2
no shutdown
fniom-4#
fniom-4#show interfaces port-channel 2 brief
Codes: L - LACP Port-channel
LAG Mode Status Uptime Ports
L 2 L2L3 up 03:33:14 Te 0/40 (Up)
fniom-4#
In the ToR unit, configure LACP on the physical ports
fniom-1#show running-config interface tengigabitethernet 0/48
!