Administrator Guide

6 Enable the monitoring FIP keepalive messages (if it is disabled) to detect if other FCoE devices are
reachable. Default: FIP keepalive monitoring is enabled.
FCoE MAP mode
keepalive
7 Configure the time interval (in seconds) used to transmit FIP keepalive advertisements. Range: 8–90
seconds. Default: 8 seconds.
FCoE MAP mode
fka-adv-period seconds
Applying an FCoE Map on Server-facing
Ethernet Ports
You can apply multiple FCoE maps on an Ethernet port or port channel. When you apply an FCoE map on a
server-facing port or port channel:
The port is configured to operate in hybrid mode (accept both tagged and untagged VLAN frames).
The associated FCoE VLAN is enabled on the port or port channel.
When you enable a server-facing Ethernet port, the servers respond to the FIP advertisements by performing
FLOGIs on upstream virtualized FCF ports. The NPG forwards the FLOGIs as FDISC messages to a SAN switch.
1 Configure a server-facing Ethernet port or port channel with an FCoE map.
CONFIGURATION mode
interface {tengigabitEthernet slot/port | port-channel num}
2 Apply the FCoE/FC configuration in an FCoE map on the Ethernet port. Repeat this step to apply an FCoE
map to more than one port.
INTERFACE or INTERFACE PORT_CHANNEL mode
fcoe-map map-name
Dell# interface tengigabitEthernet 0/0
Dell(config-if-te-0/0)# fcoe-map SAN_FABRIC_A
Dell# interface port-channel 3
Dell(config-if-te-0/0)# dcb-map SAN_DCB1
Dell(config-if-po-3)# fcoe-map SAN_FABRIC_A
3 Enable the port for FCoE transmission using the map settings.
INTERFACE mode
no shutdown
NPIV Proxy Gateway 932