Administrator Guide
• flash: (Optional) Specifies the flash drive. The default uses the flash drive. You can enter the image file
name.
• hash-value: (Optional). Specify the relevant hash published on iSupport.
• img-file: Enter the name of the Dell Networking software image file to validate
Examples: Without Entering the Hash Value for Verification
MD5
Dell# verify md5 flash://FTOS-SE-9.5.0.0.bin
MD5 hash for FTOS-SE-9.5.0.0.bin: 275ceb73a4f3118e1d6bcf7d75753459
SHA256
Dell# verify sha256 flash://FTOS-SE-9.5.0.0.bin
SHA256 hash for FTOS-SE-9.5.0.0.bin:
e6328c06faf814e6899ceead219afbf9360e986d692988023b749e6b2093e933
Examples: Entering the Hash Value for Verification
MD5
Dell# verify md5 flash://FTOS-SE-9.5.0.0.bin 275ceb73a4f3118e1d6bcf7d75753459
MD5 hash VERIFIED for FTOS-SE-9.5.0.0.bin
SHA256
Dell# verify sha256 flash://FTOS-SE-9.5.0.0.bin
e6328c06faf814e6899ceead219afbf9360e986d692988023b749e6b2093e933
SHA256 hash VERIFIED for FTOS-SE-9.5.0.0.bin
Deploying FN I/O Module
This section provides design and configuration guidance for deploying the Dell PowerEdge FN I/O Module
(FN IOM).
By default the FN IOM is in Standalone Mode. It consists of the following default settings:
Mode
Default Settings
Chassis
Management
Controller
Configuration
Yes
Stacking and VLT Disabled
Data Center
Bridging Exchange
Protocol (DCBx)
Enabled
FIP Snooping
Bridge (FSB)
Enabled on FN 410S & FN 410T; Disabled on FN 2210S
Getting Started 67