Administrator Guide

Duplex Data transmission mode: Full (allows communication in both directions at
the same time), Half (allows communication in both directions but not at
the same time), Auto (auto-negotiated transmission).
VLAN VLAN IDs of the VLANs in which the port is a member.
show fcoe-map Command Examples
Dell# show fcoe-map brief
Fabric-Name Fabric-Id Vlan-Id FC-MAP FCF-Priority Config-State
Oper-State
fid_1003 1003 1003 0efc03 128 ACTIVE
UP
fid_1004 1004 1004 0efc04 128 ACTIVE
DOWN
Dell# show fcoe-map fid_1003
Fabric Name fid_1003
Fabric Id 1003
Vlan Id 1003
Vlan priority 3
FC-MAP 0efc03
FKA-ADV-Period 8
Fcf Priority 128
Config-State ACTIVE
Oper-State UP
Members
Fc 0/0
Te 0/14 Te 0/16
Table 92. show fcoe-map Field Descriptions
Field Description
Fabric-Name Name of a SAN fabric.
Fabric ID The ID number of the SAN fabric to which FC traffic is forwarded.
VLAN ID The dedicated VLAN used to transport FCoE storage traffic between
servers and a fabric over the NPG. The configured VLAN ID must be the
same as the fabric ID.
VLAN priority FCoE traffic uses VLAN priority 3. (This setting is not user-configurable.)
FC-MAP FCoE MAC-address prefix value - The unique 24-bit MAC address prefix
that identifies a fabric.
FKA-ADV-period Time interval (in seconds) used to transmit FIP keepalive advertisements.
FCF Priority The priority used by a server to select an upstream FCoE forwarder.
FC Flex IO Modules 1102