Administrator Guide
Command Description
show fc switch
Displays the FC mode of operation and worldwide node (WWN)
name of the FN IOM with the FC Flex IO module.
show interfaces status Command Example
Dell# show interfaces status
Port Description Status Speed Duplex Vlan
Fc 0/0 Up 8000 Mbit Auto --
Fc 0/1 Down Auto Auto --
Fc 0/2 Down Auto Auto --
Fc 0/3 Down Auto Auto --
Fc 0/4 Down Auto Auto --
Fc 0/5 Down Auto Auto --
Fc 0/6 Down Auto Auto --
Fc 0/7 Down Auto Auto --
Fc 0/8 Down Auto Auto --
Fc 0/9 Down Auto Auto --
Fc 0/10 Down Auto Auto --
Fc 0/11 Down Auto Auto --
Te 1/12 Down Auto Auto --
Te 1/13 Down Auto Auto --
Te 1/14 Down Auto Auto --
Te 1/15 Down Auto Auto --
Te 1/16 Down Auto Auto --
Te 1/17 Down Auto Auto --
Te 1/18 Down Auto Auto --
Te 1/19 Up 10000 Mbit Full --
Te 1/20 Down Auto Auto --
Te 1/21 Down Auto Auto --
Table 91. show interfaces status Field Descriptions
Field Description
Port Server-facing 10GbE Ethernet (Te), 40GbE Ethernet (Fo), or fabric-facing
Fibre Channel (Fc) port with slot/port information.
Description Text description of port.
Status Operational status of port:
Ethernet ports - up (transmitting FCoE and LAN storage traffic) or down
(not transmitting traffic).
Fibre Channel ports - up (link is up and transmitting FC traffic) or down
(link is down and not transmitting FC traffic), link-wait (link is up and
waiting for FLOGI to complete on peer SW port), or removed (port has
been shut down).
Speed Transmission speed (in Megabits per second) of Ethernet and FC iports,
including auto-negotiated speed (Auto).
FC Flex IO Modules 1101