Administrator Guide
You cannot enter this command on a MASTER or Standby stack unit.
NOTE: The system reboots when the offline diagnostics complete. This is an automatic process. The
following warning message appears when you implement the offline stack-unit command:
Warning - offline of unit will bring down all the protocols and
the unit will be operationally down, except for running Diagnostics.
Please make sure that stacking/fanout not configured for Diagnostics
execution.
Also reboot/online command is necessary for normal operation after the
offline command is issued.
Proceed with Offline [confirm yes/no]:
Dell#offline stack-unit 0
Warning - offline of unit will bring down all the protocols and
the unit will be operationally down, except for running Diagnostics.
Please make sure that stacking/fanout not configured for Diagnostics execution.
Also reboot/online command is necessary for normal operation after the offline
command is issued.
Proceed with Offline [confirm yes/no]:yes
Dell#
2 Confirm the offline status.
EXEC Privilege mode
show system brief
Dell#show system brief
Stack MAC : 00:1e:c9:de:03:7b
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version
Ports
-------------------------------------------------------------------------------
-----
0 Management offline PE-FN-410S-IOA PE-FN-410S-IOA 1-0(0-1862)
12
1 Member not present
2 Member not present
3 Member not present
4 Member not present
5 Member not present
Dell#
Trace Logs
In addition to the syslog buffer, the Dell Networking OS buffers trace messages which are continuously
written by various software tasks to report hardware and software events and status information.
Each trace message provides the date, time, and name of the Dell Networking OS process. All messages are
stored in a ring buffer. You can save the messages to a file either manually or automatically after failover.
Debugging and Diagnostics 1021