Administrator Guide
802.1QTagged: Hybrid
SMUX port mode: Auto VLANs enabled
Vlan membership:
Q Vlans
U 1
T 2-4094
Native VlanId: 1
2 Assign the port to a specified group of VLANs (vlan tagged command) and re-display the port mode
status..
Dell(conf)#interface tengigabitethernet 0/1
Dell(conf-if-te-0/1)#vlan tagged 2-5,100,4010
Dell(conf-if-te-0/1)#
Dell#show interfaces switchport tengigabitethernet 0/1
Codes: U - Untagged, T - Tagged
x - Dot1x untagged, X - Dot1x tagged
G - GVRP tagged, M - Trunk, H - VSN tagged
i - Internal untagged, I - Internal tagged, v - VLT untagged, V - VLT
tagged
Name: TenGigabitEthernet 0/1
802.1QTagged: Hybrid
SMUX port mode: Admin VLANs enabled
Vlan membership:
Q Vlans
U 1
T 2-5,100,4010
Native VlanId: 1
Software show Commands
Use the show version and show system stack-unit 0 commands as a part of troubleshooting an
Aggregator’s software configuration.
Table 79. Software show Commands
Command Description
show version Display the current version of Dell Networking OS
software running on an Aggregator.
show version Command Example
Dell#show version
Dell Real Time Operating System Software
Dell Operating System Version: 2.0
Dell Application Software Version: 9-4(0-180)
Copyright (c) 1999-2014 by Dell Inc. All Rights Reserved.
Build Time: Sun Mar 30 20:15:19 PDT 2014
Build Path: /work.local/build/toolSpaces/tools05/E9-4-0/SW/SRC
Dell Networking OS uptime is 9 hour(s), 21 minute(s)
System image file is "dv-ci-stomp-tc-1-a1"
Debugging and Diagnostics 1019