Concept Guide
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information When you use the no logging on command, messages are logged only to the console.
Related Commands
logging — enables logging to the Syslog server.
logging buered — sets the logging buered parameters.
logging console — sets the logging console parameters.
logging monitor — sets the logging parameters for the terminal connections.
logging source-interface
Specify that the IP address of an interface is the source IP address of Syslog packets sent to the Syslog server.
Syntax
logging source-interface interface
To disable this command and return to the default setting, use the no logging source-interface
command.
Parameters
interface Enter the following keywords and slot/port or number information:
• For Loopback interfaces, enter the keyword loopback then a number from zero (0)
to 16383.
• For a Port Channel interface, enter the keywords port-channel then a number.
The range is from 1 to 128.
•
For a ten-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet
then the slot/port information.
• For VLAN interface, enter the keyword vlan then a number from 1 to 4094.
Defaults Not congured.
Command Modes CONFIGURATION
Supported Modes Full–Switch Mode
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information Syslog messages contain the IP address of the interface used to egress the router. By conguring the logging
source-interface command, the Syslog packets contain the IP address of the interface congured.
Related Commands
logging — enables logging to the Syslog server.
1262 Simple Network Management Protocol (SNMP) and Syslog