Concept Guide

Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
8.3.17.0 Supported on the M I/O Aggregator.
Example (all)
Dell#show environment all
-- Unit Environment Status --
Unit Status Temp Voltage TempStatus
--------------------------------------
* 1 online 66C ok 2
* Management Unit
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 Sensor7
Sensor8 Sensor9
-----------------------------------------------------------------
1 51 51 63 61 61 61 67 61
64 66
Dell#
Example (stack-unit)
Dell#show environment stack-unit
-- Unit Environment Status --
Unit Status Temp Voltage TempStatus
------------------------------------------
* 1 online 66C ok 2
* Management Unit
Dell#
Example (thermal-
sensor)
Dell#show environment thermal-sensor
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 Sensor7
Sensor8 Sensor9
-----------------------------------------------------------------
1 51 51 64 61 61 61 67 61
64 66
Dell#
show inventory
Display the switch type, components (including media), and Dell Networking OS version including hardware identication numbers and
congured protocols.
Syntax
show inventory [media slot]
Parameters
media slot (OPTIONAL) Enter the keyword media then the stack ID of the stack member you want
to display pluggable media inventory.
Defaults none
Command Modes EXEC
Supported Modes All Modes
114 Control and Monitoring