Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers
and a SAN fabric.
show fcoe-map— displays the Fibre Channel and FCoE conguration parameters in FCoE maps.
fabric-id vlan
In an FCoE map, congure the association between the dedicated VLAN used to carry FCoE trac between servers and a SAN, and the
fabric where the desired storage arrays are installed.
Syntax
fabric-id fabric-num vlan vlan-id
Parameters
fabric-id fabric-num Enter a fabric ID number that is the same as the ID number of the dedicated VLAN used
to carry FCoE storage trac to the fabric specied in the FCoE map. You can enter a
fabric ID in the range 2–4094.
vlanvlan-id Enter the ID number of the dedicated VLAN used to carry FCoE storage trac between
servers and a SAN fabric and specied with the vlan command in the FCoE map.
Defaults None
Command Modes FCOE MAP
Supported Modes Programmable-Mux (PMUX)
Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.6(0.0) Supported on the FN 2210S Aggregator.
9.3(0.0) Supported on the M I/O Aggregator.
Usage Information
In the fabric-id vlan command, the fabric and VLAN ID numbers must be the same.
In each FCoE map, the fabric ID, FC-MAP value, and FCoE VLAN parameters must be unique.
To remove a fabric-VLAN association from an FCoE map, enter the no fabric-id vlan command.
Create a VLAN and then specify the congured VLAN ID in the fabric-id vlan command. Otherwise, the
following error message is displayed.
Dell(conf-fcoe-f)#fabric-id 10 vlan 10 % Error: Vlan 10 does not exist
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers
and a SAN fabric.
show fcoe-map— displays the Fibre Channel and FCoE conguration parameters in FCoE maps.
NPIV Proxy Gateway 891