CLI Guide
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information
For specic interoperability limitations regarding the S-Tag TPID, refer to the Dell Networking OS Conguration
Guide.
Related Commands
portmode hybrid — sets a port (physical ports only) to accept both tagged and untagged frames. A port
congured this way is identied as a hybrid port in report displays.
vlan-stack trunk — species a Layer 2 port or port channel as a trunk port to the Stackable VLAN network.
vlan-stack trunk
Specify a Layer 2 port or port channel as a trunk port to the Stackable VLAN network.
Syntax
vlan-stack trunk
To remove a trunk port designation from the selected interface, use the no vlan-stack trunk command.
Defaults Not congured.
Command Modes INTERFACE
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information
Prior to using this command, to place the interface in Layer 2 mode, execute the switchport command.
To remove the trunk port designation, rst remove the port (using the no member interface command) from
all stackable VLAN-enabled VLANs.
Starting with the Dell Networking OS version 7.8.1.0, a VLAN-Stack trunk port is also allowed to be congured as a
tagged port and as an untagged port for single-tagged VLANs. When the VLAN-Stack trunk port is also a member
of an untagged VLAN, the port must be in Hybrid mode. Refer to portmode hybrid.
In the rst example, a VLAN-Stack trunk port is congured and then also made part of a single-tagged VLAN.
In the second example, the tag protocol identier (TPID) is set to 8848. The “Gi 3/10” Te 3/8 port is congured to
act as a VLAN-Stack access port, while the “TenGi 8/0” port acts as a VLAN-Stack trunk port, switching
stackable VLAN trac for VLAN 10, while also switching untagged trac for VLAN 30 and tagged trac for VLAN
40. (To allow VLAN 30 trac, the native VLAN feature is required, by executing the portmode hybrid
command. Refer to portmode hybrid in the Interfaces chapter.
Example
Dell(conf-if-Te-0/12)#switchport
Dell(conf-if-Te-0/12)#vlan-stack trunk
Dell(conf-if-Te-0/12)#show config
!
1324 VLAN Stacking