Concept Guide

View the Multicast IPMC replication table from the bShell.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} ipmc-replication
View the internal statistics for each port-pipe (unit) on per port basis.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} port-stats [detail]
View the stack-unit internal registers for each port-pipe.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} register
View the tables from the bShell through the CLI without going into the bShell.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} table-dump {table name}
Environmental Monitoring
Aggregator components use environmental monitoring hardware to detect transmit power readings, receive power readings, and
temperature updates.
To receive periodic power updates, you must enable the following command.
Enable environmental monitoring.
enable optic-info-update interval
Example of the show interfaces transceiver Command
Dell#show interfaces tengigabitethernet 0/9 transceiver
SFP is present
SFP+ 9 Serial Base ID fields
SFP+ 9 Id = 0x03
SFP+ 9 Ext Id = 0x04
SFP+ 9 Connector = 0x21
SFP+ 9 Transceiver Code = 0x00 0x00 0x00 0x00 0x00 0x04 0x00 0x00
SFP+ 9 Encoding = 0x00
SFP+ 9 BR Nominal = 0x67
SFP+ 9 Length(SFM) Km = 0x00
SFP+ 9 Length(OM3) 2m = 0x00
SFP+ 9 Length(OM2) 1m = 0x00
SFP+ 9 Length(OM1) 1m = 0x00
SFP+ 9 Length(Copper) 1m = 0x01
SFP+ 9 Vendor Rev = A
SFP+ 9 Laser Wavelength = 256 nm
SFP+ 9 CheckCodeBase = 0xf2
SFP+ 9 Serial Extended ID fields
SFP+ 9 Options = 0x00 0x00
SFP+ 9 BR max = 0
SFP+ 9 BR min = 0
SFP+ 9 Vendor SN = APF11040012888
SFP+ 9 Datecode = 110207
SFP+ 9 CheckCodeExt = 0xb3
SFP+ 9 DOM is not supported
Dell#
Recognize an Over-Temperature Condition
An overtemperature condition occurs, for one of two reasons: the card genuinely is too hot or a sensor has malfunctioned.
Inspect cards adjacent to the one reporting the condition to discover the cause.
986
Debugging and Diagnostics