Concept Guide

To congure a static MAC address (00:00:00:00:11:11) on a vlan (100) on interface whose ifIndex is (2101252), use the following command.
snmpset -v 2c -c public 10.16.129.26 1.3.6.1.4.1.6027.3.31.1.2.2.1.4.6.0.0.0.0.17.17.100.2101252
i 4
To remove the congure the above congured static MAC address, use the following command.
snmpset -v 2c -c public 10.16.129.26 1.3.6.1.4.1.6027.3.31.1.2.2.1.4.6.0.0.0.0.17.17.100.2101252
i 6
To retrieve the static MAC address congured, use the following command.
snmpget -v 2c -c public 10.16.129.26 1.3.6.1.4.1.6027.3.31.1.2.2.1.4.6.0.0.0.0.17.17.100.2101252
MIB objects for conguring MAC addresses
This section describes about the MIB table dellNetPortSecSecureMacAddrTable that contains the MAC database of the system.
The table is indexed by the following parameters:
MAC Address (Octet string of length 6 and MAC address ( in decimal) as value
VLAN ID
Table 100. MIB Objects for conguring MAC addresses
MIB Object OID Access or Permission Description
dellNetSecureMacIfIndex 1.3.6.1.4.1.6027.3.31.1.3.1.1.3 read-only Shows in which interface the
dellNetSecureMacAddress is
congured or learnt.
dellNetSecureMacAddrType 1.3.6.1.4.1.6027.3.31.1.3.1.1.4 read-only Indicates if the secure MAC address is
congured as a static, dynamic, or sticky.
Viewing the Details of MAC addresses
You can retrieve the dellNetSecureMacAddrType details, use the snmpwalk command.
To retrieve the dellNetSecureMacAddrType on a MAC address (00:00:00:00:11:11) learnt or congured on a VLAN 10, use the
following command.
snmpwalk -v 2c -c public 10.16.129.24 1.3.6.1.4.1.6027.3.31.1.3.1.1.4.6.0.0.0.0.17.17.10
SNMPv2-SMI::enterprises.6027.3.31.1.3.1.1.4.6.0.0.0.0.17.17.10 = INTEGER: 1
Transceiver Monitoring
To retrieve and display the transceiver related parameters you can perform a snmpwalk transceiver table OID to retrieve transceiver details
as per the MIB. This enables transceiver monitoring and identication of potential issues related to the transceivers on a switch.
Ensure that SNMP is enabled on the device before running a query to retrieve the transceiver information.
If Tx/Rx power, temperature, current, or voltage is not supported on optics, snmp walk returns a null ("") value.
If optics are not inserted in a port, empty string is displayed.
Example of SNMP Output for Transceiver Monitoring
Dell $ snmpwalk -v1 -c public 10.16.150.210 1.3.6.1.4.1.6027.3.11.1.3.1.1 | grep 2106373
SNMPv2-SMI::enterprises.6027.3.11.1.3.1.1.1.2113540 = STRING: "stack-unit-1 fixedmodule-5
820
Simple Network Management Protocol (SNMP)