CLI Guide

the message type. The range is from 0 to 255 for ICMP type
and from 0 to 255 for ICMP code.
count (OPTIONAL) Enter the keyword count to count packets the
filter processes.
byte (OPTIONAL) Enter the keyword byte to count bytes the
filter processes.
log (OPTIONAL) Enter the keyword log to enable the triggering
of ACL log messages.
threshold-in-
msgs count
(OPTIONAL) Enter the threshold-in-msgs keyword
followed by a value to indicate the maximum number of
ACL logs that can be generated, exceeding which the
generation of ACL logs is terminated with the seq, permit,
or
deny commands. The threshold range is from 1 to 100.
interval minutes (OPTIONAL) Enter the keyword interval followed by the
time period in minutes at which ACL logs must be
generated. The interval range is from 1 to 10 minutes.
monitor (OPTIONAL) Enter the keyword monitor to monitor traffic
on the monitoring interface specified in the flow-based
monitoring session along with the filter operation.
Defaults
By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
The default frequency at which ACL logs are generated is five minutes. By default,
flow-based monitoring is not enabled.
Command Modes ACCESS-LIST
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Added the support for flow-based monitoring on the MXL
10/40GbE Switch IO Module platform
9.3(0.0) Added the support for logging of ACLs on the MXL
10/40GbE Switch IO Module platform
9.2(0.0) Introduced on the MXL 10/40GbE Switch IO Module
platform.
Usage Information
When the configured maximum threshold is exceeded, generation of logs is
stopped. When the interval at which ACL logs are configured to be recorded
expires, the subsequent, fresh interval timer is started and the packet count for that
new interval commences from zero. If ACL logging was stopped previously
because the configured threshold is exceeded, it is re-enabled for this new interval.
752
IPv6 Access Control Lists (IPv6 ACLs)