CLI Guide
• EXEC Privilege
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.3(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
9.1.1.0 Introduced on the S5000.
Usage Information
Use the show fcoe-map command to display the FC and FCoE parameters used
to configure server-facing Ethernet (FCoE) and fabric-facing FC ports in all FCoE
maps on the switch.
In each FCoE map, the values for the fabric ID and FC-MAP that identify the SAN
fabric to which FC storage traffic is sent, and the FCoE VLAN to be used must be
unique.
An FCoE map is used to identify the SAN fabric to which FCoE storage traffic is
sent. It also virtualizes the switch with FC Flex IO module FC ports, so that they
appear to downstream server CNA ports as FCoE Forwarder (FCF) ports on an FCoE
network.
Example
Dell#show system stack-unit 0 iom-mode
Unit Boot-Mode Next-Boot
------------------------------------------------
0 standalone standalone
Dell#show fcoe-map
Fabric Name SAN_FABRIC
Fabric Type npiv
Fabric Id 1002
Vlan Id 1002
Vlan priority 3
FC-MAP 0efc00
FKA-ADV-Period 8
Fcf Priority 128
Config-State ACTIVE
Oper-State DOWN
=======================================================
Members
Fc 0/9 Fc 0/10
=======================================================
=======================================================
Dell#
Related
Commands
fcoe-map — creates an FCoE map which contains the parameters used in the
communication between servers and a SAN fabric.
562
FC FLEXIO FPORT