CLI Guide

pfc no-drop queues 1,3 or pfc no-drop queues
2-3. The range is from 0 to 3.
Defaults No lossless queues are configured.
Command Modes INTERFACE
Supported Modes Programmable-Mux (PMUX)
Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
9.2(0.0) Introduced on the M I/O Aggregator.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information
The maximum number of lossless queues globally supported on the switch is two.
The following lists the dot1p priority-queue assignments.
dot1p Value in the
Incoming Frame
Description heading
0 0
1 0
2 0
3 1
4 2
5 3
6 3
7 3
priority
Configure the priority for the PFC threshold to be allocated to the buffer space parameters.
Syntax
priority value buffer-size size pause-threshold threshold-value
resume-offset threshold-value shared-threshold-weight size
Parameters
priority Specify the priority of the queue for which the buffer space
settings apply
486
Data Center Bridging (DCB)