CLI Guide

Description: SAN_FABRIC
Fabric-id: 1002
Fcoe-vlan: 1002
Fc-map: 0x0efc00
Fcf-priority: 128
Fka-adv-period: 8000mSec
Keepalive: enable
Vlan priority: 3
Command Modes CONFIGURATION
INTERFACE
Supported Modes Programmable-Mux (PMUX)
Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.6(0.0) Supported on the FN2210S Aggregator.
9.3(0.0) Introduced on the M I/O Aggregator.
Usage Information
An FCoE map is a template used to map FCoE and FC parameters in a converged
fabric. An FCoE map is used to virtualize upstream FC ports on an FN2210S
Aggregator with the PMUX module NPIV proxy gateway so that they appear to
downstream server CNA ports as FCoE forwarder (FCF) ports on an FCoE network.
When applied to FC and Ethernet ports on an NPIV proxy gateway, an FCoE map
allows the switch to operate as an FCoE-FC bridge between an FC SAN and an
FCoE network by providing FCoE-enabled servers and switches with the necessary
parameters to log in to a SAN fabric.
On an FN2210S Aggregator a with the PMUX module NPIV proxy gateway, you
cannot apply an FCoE map applied on fabric-facing FC ports and server-facing 10–
Gigabit Ethernet ports.
An FCoE map consists of the following parameters: the dedicated FCoE VLAN used
for storage traffic, the destination SAN fabric (FC-MAP value), FCF priority used by a
server, and the FIP keepalive (FKA) advertisement timeout.
In each FCoE map, the fabric ID, FC-MAP value, and FCoE VLAN parameters must
be unique. Use one FCoE map to access one SAN fabric. You cannot use the same
FCoE map to access different fabrics.
To remove an FCoE map from an Ethernet interface, enter the no fcoe-map
map-name command in Interface configuration mode.
Data Center Bridging (DCB)