• Use the no seq sequence-number command if you know the filter’s
sequence number.
• Use the no permit {any | mac-source-address mac-source-
address-mask
} command.
Parameters
any Enter the keyword any to forward all packets received with
a MAC address.
mac-source-
address
Enter a MAC address in nn:nn:nn:nn:nn:nn format.
mac-source-
address-mask
(OPTIONAL) Specify which bits in the MAC address must
match. If no mask is specified, a mask of 00:00:00:00:00:00
is applied (in other words, the filter allows only MAC
addresses that match).
count (OPTIONAL) Enter the keyword count to count packets
processed by the filter.
byte (OPTIONAL) Enter the keyword byte to count bytes
processed by the filter.
log (OPTIONAL) Enter the keyword log to enable the triggering
of ACL log messages.
threshold-in msgs
count
(OPTIONAL) Enter the threshold-in-msgs keyword
followed by a value to indicate the maximum number of
ACL logs that can be generated, exceeding which the
generation of ACL logs is terminated with the seq, permit,
or
deny commands. The threshold range is from 1 to 100.
interval minutes (OPTIONAL) Enter the keyword interval followed by the
time period in minutes at which ACL logs must be
generated. The interval range is from 1 to 10 minutes.
monitor (OPTIONAL) Enter the keyword monitor when the rule is
describing the traffic that you want to monitor and the ACL
in which you are creating the rule is applied to the
monitored interface
Defaults Not configured.
Command Modes CONFIGURATION-MAC ACCESS LIST-STANDARD
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Added support for flow-based monitoring on the MXL
10/40GbE Switch IO Module platform.
9.3(0.0) Added support for logging of ACLs on the MXL 10/40GbE
Switch IO Module platform.
Access Control Lists (ACL)
277