CLI Guide
Version Description
9.5(0.0) Introduced the support for centisecs on the MXL 10/40GbE
Switch.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information If a switch is a MASTER and you change the hold timer, disable and re-enable VRRP
for the new hold timer value to take effect.
Related
Commands
disable — disables a VRRP group.
preempt
To preempt or become the MASTER router, permit a BACKUP router with a higher priority value.
Syntax
preempt
To prohibit preemption, use the no preempt command.
Defaults Enabled (that is, a BACKUP router can preempt the MASTER router).
Command Modes VRRP
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
priority
Specify a VRRP priority value for the VRRP group. The VRRP protocol uses this value during the MASTER
election process.
Syntax
priority priority
To return to the default value, use the no priority command.
Parameters
priority Enter a number as the priority. Enter 255 only if the router’s
virtual address is the same as the interface’s primary IP
address (that is, the router is the OWNER). The range is from
1 to 255. The default is 100.
Defaults 100
Virtual Router Redundancy Protocol (VRRP)
1533