CLI Guide

14 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 22
Dell#
show rmon hc-alarm
Display the contents of RMON High-Capacity alarm table.
Syntax
show rmon hc-alarm [index] [brief]
Parameters
index (OPTIONAL) Enter the table index number to display just
that entry.
brief (OPTIONAL) Enter the keyword brief to display the RMON
High-Capacity alarm table in an easy-to-read format.
Defaults none
Command Modes EXEC
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Example (Index)
Dell#show rmon hc-alarm 1
RMON high-capacity alarm entry 2
object: 1.3.6.1.2.1.2.2.1.4.2099844
sample interval: 10
sample type: delta value.
value: 0, value status: positive
alarm type: rising or falling alarm.
alarm rising threshold value: positive.
rising threshold: 500, RMON event index: 3
alarm falling threshold value: positive.
falling threshold: 300, RMON event index: 4
alarm sampling failed 0 times.
alarm owner:
alarm storage type: non-volatile.
alarm status: OK
Dell#
Example (Brief)
Dell#show rmon hc-alarm brief
index SNMP OID
----------------------------------
1290
Remote Monitoring (RMON)