CLI Guide

Parameters
media slot (OPTIONAL) Enter the keyword media then the stack ID of the stack member you want to display pluggable media inventory.
Defaults none
Command Modes EXEC
Supported Modes All Modes
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
Usage Information If there are no fiber ports in the unit, just the header under show inventory media displays. If there are fiber ports but no optics inserted, the output
displays "Media not present or accessible".
Example
Dell#show inventory
System Type : PE-FN-410S-IOA
System Mode : 1.0
Software Version : 1-0(0-1859)
Unit Type Serial Number Part Number Rev Piece Part ID Rev Svc Tag Exprs Svc Code
---------------------------------------------------------------------------------------------------------------------
* 0 PowerEdge-FN-410S-IOA TW000000000020 07NVPVX01 X01 TW-07NVPV-00000-000-0020 X01 N/A N/A
* - Management Unit
Software Protocol Configured
--------------------------------------------------------------
DCBX
FIP Snooping
IGMP
iSCSI
LLDP
SNMP
Dell#
Example (media)
Dell#show inventory media ?
<0-5> Slot number
| Pipe through a command
Dell#show inventory media
Slot Port Type Media Serial Number F10Qualified
------------------------------------------------------------------------------
0 9 SFP+ 10GBASE-SR AHJ0BU3 Yes
0 10 SFP+ 10GBASE-CU5M APF125100446U1 Yes
0 11 SFP+ 10GBASE-SR CD23FM12H Yes
0 12 SFP+ 10GBASE-SR CD23FM0XT Yes
Dell#