Administrator Guide
Dell(config-fcoe-name)# fc-map 0efc00
Dell(config-fcoe-name)# keepalive
Dell(config-fcoe-name)# fcf-priority 128
Dell(config-fcoe-name)# fka-adv-period 8
5 Enable an upstream FC port:
Dell(config)# interface fibrechannel 0/0
Dell(config-if-fc-0)# no shutdown
6 Enable a downstream Ethernet port:
Dell(config)#interface tengigabitEthernet 0/0
Dell(conf-if-te-0)# no shutdown
Displaying NPIV Proxy Gateway Information
To display information on the NPG operation, use the show commands in the following table
Table 102. Displaying NPIV Proxy Gateway Information
Command Description
show interfaces status
Displays the operational status of Ethernet and Fibre Channel interfaces on the FN
IOM with the FC Flex IO module, NPG.
NOTE: Although the show interface status command displays the Fiber
Channel (FC) interfaces with the abbreviated label of 'Fc' in the output,
if you attempt to specify a FC interface by using the interface fc
command in the CLI interface, an error message is displayed. You must
congure FC interfaces by using the interface fi command in
CONFIGURATION mode.
show fcoe-map [brief | map-name]
Displays the Fibre Channel and FCoE conguration parameters in FCoE maps.
Enter the brief keyword to display an overview of currently congured FCoE maps.
Enter the name of an FCoE map to display the FC and FCoE parameters
congured in the map to be applied on FN IOM with the FC Flex IO module
Ethernet (FCoE) and FC ports.
show qos dcb-map map-name
Displays conguration parameters in a specied DCB map.
show npiv devices [brief]
Displays information on FCoE and FC devices currently logged in to the NPG.
show fc switch
Displays the FC mode of operation and worldwide node (WWN) name of the FN
IOM with the FC Flex IO module.
show interfaces status Command Example
Dell# show interfaces status
Port Description Status Speed Duplex Vlan
Fc 0/0 Up 8000 Mbit Auto --
Fc 0/1 Down Auto Auto --
FC Flex IO Modules