Administrator Guide
• Change the default directory.
EXEC Privilege mode
cd directory
You can change the default storage location to the USB Flash, as shown. File management commands then apply to the USB Flash rather
than the internal Flash. The bold lines show that no le system is specied and that the le is saved to an USB Flash.
Dell#cd usbflash:
Dell#
copy running-config test
!
3998 bytes successfully copied
DellS#dir
Directory of usbflash:
1 drwx 4096 Jan 01 1980 00:00:00 +00:00 .
2 drwx 2048 May 02 2012 07:05:06 +00:00 ..
3 -rwx 1272 Apr 29 2011 16:15:14 +00:00 startup-config
4 -rwx 3998 May 11 2011 23:36:12 +00:00 test
View the Command History
The command-history trace feature captures all commands entered by all users of the system with a time stamp and writes these
messages to a dedicated trace log buer.
The system generates a trace message for each executed command. No password information is saved to the le.
To view the command-history trace, use the show command-history command.
Example of the show command-history Command
Dell#show command-history
[5/18 21:58:32]: CMD-(TEL0):[enable]by admin from vty0 (10.11.68.5)
[5/18 21:58:48]: CMD-(TEL0):[configure]by admin from vty0 (10.11.68.5)
- Repeated 1 time.
[5/18 21:58:57]: CMD-(TEL0):[interface port-channel 1]by admin from vty0 (10.11.68.5)
[5/18 21:59:9]: CMD-(TEL0):[show config]by admin from vty0 (10.11.68.5)
[5/18 22:4:32]: CMD-(TEL0):[exit]by admin from vty0 (10.11.68.5)
[5/18 22:4:41]: CMD-(TEL0):[show interfaces port-channel brief]by admin from vty0
(10.11.68.5)
Using HTTP for File Transfers
Stating with Release 9.3(0.1), you can use HTTP to copy les or conguration details to a remote server. To transfer les to an external
server, use the
copy source-le-url http://host[:port]/le-path command.
Enter the following source-le-url keywords and information:
• To copy a le from the internal FLASH, enter ash:// followed by the lename.
• To copy the running conguration, enter the keyword running-cong.
• To copy the startup conguration, enter the keyword startup-cong.
• To copy a le on the USB device, enter usbash:// followed by the lename.
In the Dell Networking OS release 9.8(0.0), HTTP services support the VRF-aware functionality. If you want the HTTP server to use a VRF
table that is attached to an interface, congure that HTTP server to use a specic routing table. You can use the ip http vrf command
to inform the HTTP server to use a specic routing table. After you congure this setting, the VRF table is used to look up the destination
address.
NOTE
: To enable HTTP to be VRF-aware, as a prerequisite you must rst dene the
VRF.
58 Getting Started