Users Guide

Related Commands
show interfaces switchport — displays the conguration of switchport (Layer 2) interfaces on the switch.
vlan-stack trunkspecies an interface as a trunk port to the Stackable VLAN network.
rate-interval
Congure the trac sampling interval on the selected interface.
Syntax
rate-interval seconds
Parameters
seconds Enter the number of seconds for which to collect trac data. The range is from 5 to 299
seconds.
NOTE: For 0 to 5 seconds, polling occurs every 5 seconds. For 6 to 10 seconds,
polling occurs every 10 seconds. For any other value, polling occurs every 15
seconds.
Defaults 299 seconds
Command Modes INTERFACE
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information The output of the show interfaces command displays the congured rate interval, along with the collected
trac data.
Related Commands show interfaces — displays information on physical and virtual interfaces.
rate-interval (Conguration Mode)
Congure the trac sampling interval for all physical and logical port-channel interfaces globally. The support to congure rate-interval
globally enables you to modify the default interval rate for all physical and logical interfaces at one time.
Syntax
rate-interval seconds
Use the no rate-interval command to remove the sampling interval conguration.
Parameters
seconds Enter the number of seconds for which to collect trac data. The range is from 5 to 299
seconds.
NOTE: Because polling occurs every 15 seconds, the number of seconds
designated here round to the multiple of 15 seconds lower than the entered
value. For example, if 44 seconds is designated, it rounds to 30; 45 to 59
seconds rounds to 45. If you congure this value to be less than 5, then the
entire buer is cleared; the show int stats command shows the rate
information to be 0 as the polling interval is less than 5.
Interfaces 557