Users Guide
fragments Enter the keyword fragments to use ACLs to control packet fragments.
log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
threshold-in msgs
count
(OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate
the maximum number of ACL logs that can be generated, exceeding which the generation
of ACL logs is terminated. with the seq, permit, or deny commands. The threshold
range is from 1 to 100.
interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at
which ACL logs must be generated. The time interval range is from 1 to 10 minutes.
monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the trac that you
want to monitor and the ACL in which you are creating the rule is applied to the
monitored interface.
Defaults By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which
ACL logs are generated is ve minutes. By default, ow-based monitoring is not enabled.
Command Modes ACCESS-LIST
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Added the support for ow-based monitoring on theMXL 10/40GbE Switch IO Module
platform.
9.3(0.0) Added the support for logging of ACLs on the MXL 10/40GbE Switch IO Module
platform.
Usage Information
When the congured maximum threshold is exceeded, generation of logs is stopped. When the interval at which
ACL logs are congured to be recorded expires, the subsequent, fresh interval timer is started and the packet
count for that new interval commences from zero. If ACL logging was stopped previously because the congured
threshold is exceeded, it is re-enabled for this new interval.
If ACL logging is stopped because the congured threshold is exceeded, it is re-enabled after the logging interval
period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You
can congure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs
that are associated with egress interfaces.
You can activate ow-based monitoring for a monitoring session by entering the flow-based enable
command in the Monitor Session mode. When you enable this capability, trac with particular ows that are
traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both
the ingress and egress directions. Flow-based monitoring conserves bandwidth by monitoring only specied trac
instead all trac on the interface. This feature is particularly useful when looking for malicious trac. It is available
for Layer 2 and Layer 3 ingress and egress trac. You may specify trac using standard or extended access-lists.
This mechanism copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port.
The source port is the monitored port (MD) and the destination port is the monitoring port (MG).
266 Access Control Lists (ACL)