Users Guide
Debugging and Diagnostics
This chapter contains the following sections:
• Oine Diagnostic Commands
• Hardware Commands
Topics:
• Oine Diagnostic Commands
• Hardware Commands
• clear hardware stack-unit
• clear hardware system-ow
• show hardware layer2 acl
• show hardware layer3
• diag stack-unit
• hardware watchdog
• online stack-unit
• oine stack-unit
• show diag
• show hardware stack-unit
• show hardware system-ow
• show hardware buer interface
• show hardware counters interface interface
• show hardware drops
Oine Diagnostic Commands
The oine diagnostics test suite is useful for isolating faults and debugging hardware. While tests are running, the Dell Networking OS
results are saved as a text le (TestReport-SU-X.txt) in the ash directory. The
show file command is available only on Master and
Standby.
Important Points to Remember
• Oine diagnostics can only be run when the unit is oine.
• Oine diagnostics cannot be run in Stacking mode.
• You can only run oine diagnostics on a unit to which you are connected via the console. In other words, you cannot run diagnostics on
a unit to which you are connected via a stacking link.
• Diagnostic results are stored in a le (TestReport-SU-X.txt) in the ash directory. To review the results, use the show file command,
which prints the results to the screen.
• Diagnostics only test connectivity, not the entire data path.
The oine diagnostics commands are:
• diag stack-unit
69
Debugging and Diagnostics 1409