Users Guide

Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO
module.
Usage Information
Use the show fcoe-map command to display the FC and FCoE parameters used to congure server-facing
Ethernet (FCoE) and fabric-facing FC ports in all FCoE maps on a switch with the FC Flex IO module NPIV proxy
gateway.
In each FCoE map, the values for the fabric ID and FC-MAP that identify the SAN fabric to which FC storage
trac is sent, and the FCoE VLAN to be used must be unique.
An FCoE map is used to identify the SAN fabric to which FCoE storage trac is sent and to virtualize the switch
with the FC Flex IO module FC ports so that they appear to downstream server CNA ports as FCoE Forwarder
(FCF) ports on an FCoE network.
The following table describes the show fcoe-map brief output shown in the example below.
Field Description
Fabric-Name Name of a SAN fabric.
Fabric ID The ID number of the SAN fabric to which FC trac is forwarded.
VLAN ID The dedicated FCoE VLAN used to transport FCoE storage trac between servers and a
fabric over the NPIV proxy gateway. The congured VLAN ID must be the same as the
fabric ID.
FC-MAP FCoE MAC address-prex value - The unique 24-bit MAC address prex that identies a
fabric.
FCF Priority The priority used by a server to select an upstream FCoE forwarder.
Cong-State Indicates whether the congured FCoE and FC parameters in the FCoE map are valid:
Active (all mandatory FCoE and FC parameters are correctly congured) or Incomplete
(either the FC-MAP value, fabric ID, or VLAN ID are not correctly congured).
Oper-State Operational status of link to the fabric: Up (link is up and transmitting FC trac), Down
(link is down and not transmitting FC trac), Link-wait (link is up and waiting for FLOGI to
complete on peer FC port), or Removed (port has been shut down).
The following table describes the show fcoe-map map-name output shown in the example below.
Field Description
Fabric-Name Name of a SAN fabric.
Fabric ID The ID number of the SAN fabric to which FC trac is forwarded.
VLAN ID The dedicated FCoE VLAN used to transport FCoE storage trac between servers and a
fabric over the NPIV proxy gateway. The congured VLAN ID must be the same as the
fabric ID.
VLAN priority FCoE trac uses VLAN priority 3. (This setting is not user-congurable.)
FC-MAP FCoE MAC address-prex value - The unique 24-bit MAC address prex that identies a
fabric.