Users Guide
Command History
Version Version
9.9(0.0) Introduced on the FN IOM.
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO
module.
Usage Information
To delete the FIP keepalive time period from an FCoE map, enter the no fka-adv-erpiod command.
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers
and a SAN fabric.
show fcoe-map — displays the Fibre Channel and FCoE conguration parameters in FCoE maps.
interface vlan (NPIV proxy gateway)
Create a dedicated VLAN to be used to send and receive Fibre Channel trac over FCoE links between servers and a fabric over a switch
with the FC Flex IO module NPIV proxy gateway.
Syntax
interface vlan vlan-id
Parameters
vlan-id Enter a number as the VLAN Identier. The range is 1 to 4094.
Defaults Not congured.
Command Modes CONFIGURATION
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.3.0.0 Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO
module congured as an NPIV proxy gateway.
Usage Information
FCoE storage trac received from servers on a switch with the FC Flex IO module NPIV proxy gateway is de-
capsulated into Fibre Channel packets and forwarded over FC links to SAN switches in a specied fabric. You must
congure a separate FCoE VLAN for each fabric to which FCoE trac is forwarded. Any non-FCoE trac sent on
a dedicated FCoE VLAN will be dropped.
You congure the association between a dedicated VLAN, which carries FCoE trac from server CNAs over the
NPIV proxy gateway to a SAN fabric in which destination storage arrays are installed, in an FCoE map by using the
fabric id vlan command.
When you apply an FCoE map to a server-facing Ethernet port, the port is automatically congured as a tagged
member of the FCoE VLAN.
For more information about VLANs and the commands to congure them, refer to the Virtual LAN (VLAN)
Commands section of the Layer 2 chapter.
Example (Single
Range)
FTOS(conf)#interface vlan 10
FTOS(conf-if-vl-3)#
FC Flex IO Modules 1403