Users Guide

Parameters
seconds Specify the time (in seconds) to wait for the upstream port channel (LAG 128) to come
back up before server ports are brought down. The range is from 1 to 120.
Command Modes UPLINK-STATE-GROUP
Supported Modes Standalone, Stacking, VLT
Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
9.2(0.0) Supported on the M I/O Aggregator.
Usage Information This command is not supported in Programmable-Mux mode.
description
Enter a text description of an uplink-state group.
Syntax
description text
Parameters
text Text description of the uplink-state group. The maximum length is 80 alphanumeric
characters.
Defaults none
Command Modes UPLINK-STATE-GROUP
Supported Modes Programmable-Mux (PMUX)
Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
9.2(0.0) Supported on the M I/O Aggregator.
Example
Dell(conf-uplink-state-group-16)# description test
Dell(conf-uplink-state-group-16)#
Related Commands uplink-state-group — creates an uplink-state group and enables the tracking of upstream links.
downstream
Assign a port or port-channel to the uplink-state group as a downstream interface.
Syntax
downstream interface
1344 Uplink Failure Detection (UFD)