Users Guide
redundancy force-failover stack-unit
Force the standby unit in the stack to become the management unit.
Syntax
redundancy force-failover stack-unit
Defaults Not enabled.
Command Modes EXEC Privilege
Supported Modes Full–Switch Mode
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
reset stack-unit
Reset any designated stack member except the management unit (master unit).
Syntax
reset stack-unit 0–5 hard
Parameters
0–5 Enter the stack member unit identier of the stack member to reset.
hard Reset the stack unit if the unit is in a problem state.
Defaults none
Command Modes EXEC Privilege
Supported Modes All Modes
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.6.(0.0) Supported on the FN I/O Aggregator.
8.3.17.0 Supported on the M I/O Aggregator.
Usage Information
This command is supported on the M I/O, FN410S, and FN410T Aggregators
Resetting the management unit is not allowed and an error message displays if you try to do so. Resetting is a soft
reboot, including ushing the forwarding tables.
You can run this command directly on the stack standby unit (Standby Master) to reset the standby. You cannot
reset any other unit from the standby unit
Example
Dell#show system brief
Stack MAC : 00:1e:c9:f1:00:9b
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
---------------------------------------------------------------------------------
---
0 Management online I/O-Aggregator I/O-Aggregator 8-3-17-46 56
1 Standby online I/O-Aggregator I/O-Aggregator 8-3-17-46 56
2 Member not present
3 Member not present
1262 Stacking Commands