Users Guide
* Management Unit
Dell#
Example (thermal-
sensor)
Dell#show environment thermal-sensor
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 Sensor7
Sensor8 Sensor9
-----------------------------------------------------------------
1 51 51 64 61 61 61 67 61
64 66
Dell#
show inventory
Display the switch type, components (including media), and Dell Networking OS version including hardware identication numbers and
congured protocols.
Syntax
show inventory [media slot]
Parameters
media slot (OPTIONAL) Enter the keyword media then the stack ID of the stack member you want
to display pluggable media inventory.
Defaults none
Command Modes EXEC
Supported Modes All Modes
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
Usage Information If there are no ber ports in the unit, just the header under show inventory media displays. If there are ber
ports but no optics inserted, the output displays "Media not present or accessible".
Example
Dell#show inventory
System Type : PE-FN-410S-IOA
System Mode : 1.0
Software Version : 1-0(0-1859)
Unit Type Serial Number Part Number Rev Piece Part ID Rev
Svc Tag Exprs Svc Code
-----------------------------------------------
* 0 PowerEdge-FN-410S-IOA TW000000000020 07NVPVX01 X01
TW-07NVPV-00000-000-0020 X01 N/A N/A
* - Management Unit
Software Protocol Configured
------------------------------------------------
DCBX
FIP Snooping
IGMP
iSCSI
LLDP
SNMP
Dell#
Example (media)
Dell#show inventory media ?
<0-5> Slot number
| Pipe through a command
Dell#show inventory media
Slot Port Type Media Serial Number F10Qualified
------------------------------------------------------
0 9 SFP+ 10GBASE-SR AHJ0BU3 Yes
0 10 SFP+ 10GBASE-CU5M APF125100446U1 Yes
0 11 SFP+ 10GBASE-SR CD23FM12H Yes
0 12 SFP+ 10GBASE-SR CD23FM0XT Yes
114 Control and Monitoring