Deployment Guide

Command Modes CONFIGURATION
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information To dene a password for the level to which you are assigning privilege or access, use the enable password
command.
privilege level (LINE mode)
Change the access level for users on the terminal lines.
Syntax
privilege level level
To delete access to a terminal line, use the no privilege level level command.
Parameters
level level
Enter the keyword level then a number for the access level. The range is from 0 to 15.
Level 1 is EXEC mode and Level 15 allows access to all CLI modes.
Defaults level = 15
Command Modes LINE
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
banner exec
Congure a message that is displayed when your enter EXEC mode.
Syntax
banner exec c line c
To delete a banner, use the no banner exec command.
Parameters
c Enter the keywords banner exec, then enter a character delineator, represented here
by the letter c. Press ENTER.
line Enter a text string for your banner message ending the message with your delineator. In
the following example, the delineator is a percent character (%); the banner message is
“testing, testing”.
Defaults No banner is displayed.
1138 Security