CLI Guide
description (for FCoE maps)
In an FCoE map, add a text description of the FCoE and FC parameters used to transmit storage trac over a Switch with the FC Flex IO
module NPIV proxy gateway in a converged fabric.
Syntax
description text
Parameters
text Enter a maximum of 32 characters.
Defaults None
Command Modes FCOE MAP
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO
module.
Usage Information
The text description is displayed in show fcoe-map command output.
Related Commands
fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers
and a SAN fabric.
show fcoe-map — displays the Fibre Channel and FCoE conguration parameters in FCoE maps.
fabric
Apply an FCoE map on a fabric-facing Fibre Channel (FC) port.
Syntax
fabric map-name
Parameters
map-name Maximum: 32 alphanumeric characters.
Defaults None
Command Modes INTERFACE FIBRE_CHANNEL
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO
module.
Usage Information
An FCoE map is a template used to map FCoE and FC parameters in a converged fabric. An FCoE map is used to
virtualize upstream FC ports on a switch with the FC Flex IO module NPIV proxy gateway so that they appear to
1366 FC Flex IO Modules