Release Notes
Dell - Internal Use - Confidential
Page 9 4/1/2016
Release Notes— Fluid Cache for SAN for VMware Systems
Not all Fluid Cache VSAs Started Correctly After a Cluster Shutdown or
ESX Host Power Fail
ISSUE: Under some circumstances, VSAs are not started correctly following a cluster shutdown
and restart, or an ESXi host power fail. This would appear in the EM console as a server that
has not joined the cluster or cache devices are missing on a server.
WORKAROUND: Using vSphere, reboot the VSA on the server that is reporting issues.
Unmapping Multiple Cached Volumes Can Leave Cluster in a Degraded
State
ISSUE: In some circumstances, during the unmapping of multiple cached volumes, Fluid Cache
servers can be left in a degraded state. This would appear in the EM console as a server that has
left the cluster or a server that is missing cache devices.
WORKAROUND: Using vSphere, reboot the VSA on the server that is reporting issues.