Administrator Guide

Information Displays Differently Between Storage
Centers and Fluid Cache Clusters
The Fluid Cache Clusters display shows information from the Fluid Cache server perspective while the
Storage Centers display shows information from the Storage Center perspective. If there is a
communication issue between the Fluid Cache servers and the Storage Center, they may each show that
condition differently.
There is some latency in gathering information from the Fluid Cache servers by both Data Collector and
the Storage Center as well as from the Dell Storage Client gathering information from Data Collector. It
could take several minutes for all parts of the system to synchronize and show a consistent view.
Verify That All Parts of the Fluid Cache Cluster are
Communicating with Each Other
If the Dell Storage Client displays a "reconnect" message in the Fluid Cache display for a Fluid Cache
cluster it means that EM is no longer able to communicate with the Fluid Cache cluster through the
management network.
Verify that the network is operational between the Data Collector server and the Fluid Cache servers
using a network tool such as ping.
If ping works but a reconnect to that address continues to fail, make sure that the Fluid Cache
software is operational on the server.
If the EM client displays a red mark over the cluster in the Storage Centers view of the cluster, it means
that the Storage Center is reporting that it cannot communicate with the cluster servers over the
management network.
Verify that the network is operational between the cluster servers and the Storage Center by using a
network tool such as ping.
Note that it may take several minutes for the Storage Center to report the cluster status (down or up).
Verify the Data Path is Working
The Storage Centers server view is present if the Storage Center is able to see data connections to the
cluster. The HBAs will be have a red mark if there are problems.
The Fluid Cache Clusters server view will show the HBAs from the Fluid Cache Servers perspective.
Depending on the server and its operating system, conditions such as connectivity may not be visible
from this view.
When checking for data connectivity, always check the Storage Centers view first.
The Cluster in the Fluid Cache Clusters Display is Marked
Red
Take the following into consideration when troubleshooting this problem.