Owners Manual
Preparing the Cache Network Switch
• For a schematic of an example Fluid Cache installation, see Example Cabling Diagram.
• For configuration tasks for a supported Dell Networking switch, see Configuring a Dell Networking
Switch. For all other switches, see the manufacturer’s documentation.
• For a list of supported switches, see Requirements for Fluid Cache.
1. Connect the ports on the network adapter to properly configured ports on a network switch.
NOTE: A redundant switch configuration is recommended.
If you have two switches for redundancy, on all of the cache network adapters, you must connect
port 1 to one switch and port 2 to the other switch.
2. Make sure that all ports used in the cache network have the following settings:
• The ports are in layer 2 mode.
• The ports are in an untagged state.
• The switch firmware is up to date.
• Flow control (transmit and receive) is enabled and Data Center Bridging (DCB) is disabled.
NOTE: Enabling flow control is a requirement for Fluid Cache.
3. Save the running configuration.
4. To implement the changes, restart the switch.
18