Release Notes
Release Notes— Fluid Cache for SAN for VMware Systems
Known Issues Arising from Third Party Software
The following issues are not caused by Fluid Cache itself, but arise from known issues in third
party software.
Cannot Enable Passthrough for NVMe Device in vSphere Web Client
ISSUE: Using the vSphere web client, you cannot enable passthrough for Samsung NVMe SSD
devices.
WORKAROUND: Enable passthrough using the desktop version of vSphere.
Known Issues in Fluid Cache for SAN 2.0
The following are known issues in Fluid Cache for SAN 2.0.
Removing a Server from a Cluster
ISSUE: If you try to remove a server from a cluster before shutting down the server, Enterprise
Manager displays a message saying that the action is not allowed.
WORKAROUND: Shut down the VSA from vSphere. Then continue with the Deployment Guide
procedure “Removing a Server from a Cluster.”
Removing Multiple Servers from a Cluster
ISSUE: Under some circumstances, remove more than one server at a time from a cluster may
cause I/O to hang or data to be lost.
WORKAROUND: Avoid removing more than one server at a time from a cluster.