Setup Guide
Table Of Contents
- Dell 8/4Gbps FC SAN Module
- Dell 8/4Gbps FC SAN Module
- In this guide
- Overview
- Unpacking and installing the FC SAN Module
- Cabling guidelines
- Configuring the FC SAN Module
- Appendix A
- Dell 8/4Gbps FC SAN 模块
- Dell 8/4Gbps FC SAN 模組
- Module SAN FC 8/4 Gb/s Dell
- Dans ce guide
- Présentation
- Déballage et installation du Module SAN FC
- Consignes de câblage
- Configuration du module SAN FC
- Annexe A
- Dell 8/4Gbps FC SAN-Modul
- Inhalt dieser Anleitung
- Übersicht
- Auspacken und Installieren des FC SAN-Moduls
- Richtlinien für die Verkabelung
- Konfigurieren des FC SAN-Moduls
- Anhang A
- Modul FC SAN Dell 8/4Gbps
- Dalam panduan ini
- Ikhtisar
- Membuka dan memasang Modul FC SAN
- Panduan perkabelan
- Mengonfigurasikan Modul FC SAN
- Lampiran A
- Dell 8/4Gbps FC SAN モジュール
- Dell 8/4Gbps FC SAN 모듈
- Módulo SAN de Canal de Fibra de 8/4Gbps da Dell
- Neste guia
- Visão geral
- Desembalar e instalar o Módulo SAN
- Diretrizes de cabeamento
- Configurar o módulo SAN de Canal de Fibra
- Apêndice A
- Módulo SAN FC de 8/4 Gbps de Dell
- En esta guía
- Descripción general
- Cómo desempaquetar e instalar el Módulos SAN FC
- Pautas para el cableado
- Configuración del módulo SAN FC
- Apéndice A
- Dell 8/4Gbps FC SAN Module
- Bu kýlavuzda
- Genel Bakýþ
- SAN I/O Module’ü paketten çýkarma FC SAN Module
- Kablo sistemi rehberi
- FC SAN Module’ü Yapýlandýrma
- Ek A
6 Dell 8/4Gbps FC SAN Module Getting Started Guide
53-1001963-01
• Flow Control: None
For LINUX or UNIX
a. Enter the following at the command prompt:
tip /dev/ttyb -9600
b. When the terminal application stops reporting information, press Enter to display the login prompt.
c. Log in to the default administrative account using the following identification:
Login: admin
Password: password
d. When prompted either change the administrative password, or press Ctrl-C to bypass.
Task 2: Changing the IP address
1. Verify that the FC SAN Module has completed POST. When POST is complete, the port status and FC SAN Module
power and status LEDs return to a standard healthy state.
2. Enter the CLI ipAddrSet command.
Follow on-screen instructions and supply the correct information, as shown in the following example.
switch:admin> ipaddrset
Ethernet IP Address [10.77.77.77]:10.32.53.47
Ethernet Subnetmask [255.255.255.0]:255.255.240.0
Fibre Channel IP Addresss [none]:
Fibre Channel Subnetmask [none]:
Gateway IP Address [0.0.0.0]:10.32.48.1
DHCP [Off]:
IP address is being changed...Done.
3. Enter ipAddrShow at the prompt to verify that the address was correctly set.
Using the CMC CLI to set the IP address
Use the following steps to connect modify the FC SAN Module IP address through the CMC CLI.
1. Establish a Telnet session to the CMC CLI.
2. At the command prompt, type connect switch-x where x is the bay where the FC SAN Module is installed. For
example, switch-x can be:
• Switch-3 for FC SAN Module installed in bay B1.
• Switch-4 for FC SAN Module installed in bay B2.
• Switch-5 for FC SAN Module installed in bay C1.
• Switch-6 for FC SAN Module installed in bay C2.
3. At the login prompt, enter the default user name as “admin” and password as “password”.
4. Use the appropriate CLI commands to change the IP address of the selected FC SAN module. Refer to your
Blade Server Enclosure CLI documentation.