Install Guide

PS6210 Install and SetupGuide
2 Rack Mounting the Array
• Thereisatleast4.1cm(1.6inches)betweentherackdoorandthefrontofthearraytoaccommodatethe
arrayfrontbezel.
• Therack(withinstalledarrays)meetsthesafetyrequirementsofUL60950-1andIEC60950-1,availableat
ulstandardsinfonet.ul.com/scopes/scopes.asp?fn=60950-1.html.
• Mountthearrayinahorizontalorientationoryouwillvoidyourarraywarrantyandsupportcontract.
Environmental Requirements
Theracklocationmustmeetthefollowingenvironmentalrequirements:
• Thepowersourcecansupplyavoltagerangeof100Vto240VAC.
• Thepowersourcehassufficientelectricaloverloadprotection:
InNorthAmerica,connectthearraytoasourceofpowerwithover-currentprotectionprovidedbya
doublepole20Aorlessdevice(UL489circuitbreakers).
InEurope,theover-currentprotectionmustbeprovidedbya20Aorlessdevice(IECcircuitbreakers).
• Thereissufficientspaceforairflowinfrontofandbehindthearray.
• Thelocationisproperlyvented.
• YourenvironmentsupportsalloftherequirementslistedintheTechnical Specifications on page 31.
Protecting Hardware
ProtectyourPSSeriesarrayfromelectrostaticdischarge.Whenhandlingarrayhardware,useanelectrostatic
wriststraporasimilarformofprotection.Touseawriststrap:
1. Connectthesteelsnaponthecoilcordtothestudontheelasticband.SeeFigure1.
Figure 1: Using an Electrostatic Wrist Strap
2. Fitthebandtightlyaroundyourwrist.
3. Connectthebandtoground.Youcaneitherplugthebananaconnectorintoamatchinggroundedreceptacle,
orattachittothematchingalligatorclipandconnectthecliptoagroundeddevice.Examplesofan
appropriategroundwouldbeanESDmatorthemetalframeofagroundedpieceofequipment.
Shipping Box Contents and Required Hardware
Makesureyouhavealltheitemssuppliedintheshippingbox,describedinTable1.Youmustprovideadditional
hardwarethatisspecifictoyourenvironmentandnotincludedintheshippingbox.SeeTable2.
4