Owner's Manual
Table 3. Rules — Dell EqualLogic Storage Management Pack
Alert Description Severity
Dell EqualLogic: Temperature
Sensor High Threshold Alert
High Threshold Enclosure Temperature
sensor <
temperature sensor name
> is
at <
value
> °C. Temperature sensor is
now in <
status
> state.
Based on current state of temperature
threshold.
Dell EqualLogic: Temperature
Sensor Low Threshold Alert
Low Threshold Enclosure Temperature
sensor <
temperature sensor name
> is
at <
value
> °C. Temperature sensor is
now in <
status
> state.
Based on current state of temperature
threshold.
Dell EqualLogic: Fan Speed High
Threshold Alert
Speed of enclosure fan <
fan name
> is
<
speed
> rpm. Sensor is now in
<
status
> state.
Based on current state of fan speed
threshold.
Dell EqualLogic: Fan Speed Low
Threshold Alert
Speed of enclosure fan <
fan name
> is
<
speed
> rpm. Sensor is now in
<
status
> state.
Based on current state of fan speed
threshold.
Dell EqualLogic: Power Supply Fan
Status Alert
Status of power supply fan <
power
supply
> has changed to <
status
>.
Based on power supply fan health.
Dell EqualLogic: Power Supply
Status Alert
Status of Power Supply module <
power
supply
> has changed to <
status
>.
Based on power supply health.
Dell EqualLogic: RAID Set Double
Faulted Alert
Double fault has been detected in the
RAID set. User intervention is required
Critical
Dell EqualLogic: Both the Fan Trays
Removed Alert
Both fan trays of the member have
been removed from the chassis.
Critical
Dell EqualLogic: RAID Lost Cache
Alert
RAID driver is unable to recover the
battery-backed cache. User
intervention is required to initialize the
disk array.
Critical
Dell EqualLogic: One Fan Tray
Removed Alert
One of the fan trays of the member has
been removed from the chassis.
Critical
Dell EqualLogic: RAID Lost Block
Table Full Alert
RAID lost block table is full. Critical
Dell EqualLogic: Battery Less Than
72 Hours Alert
Insufficient battery charge to last a 72
hour power outage.
Warning
Dell EqualLogic : RAID Orphan
Cache Alert
RAID driver found data in the battery-
backed cache with no matching disk.
User intervention is required.
Critical
Dell EqualLogic: Multiple RAID Sets
Found Alert
Multiple RAID sets found. The array
cannot choose which one to initialize.
Critical
Dell EqualLogic: NVRAM Battery
Failed Alert
NVRAM battery failed and cannot be
used.
Critical
Dell EqualLogic: Critical Hardware
Component Failed Alert
A critical hardware component of the
member has failed.
Critical
Dell EqualLogic: Incorrect Control
Module Inserted Alert
An incorrect control module has been
inserted in the chassis.
Critical
Dell EqualLogic: High Battery
Temperature Alert
Cache battery temperature exceeds the
upper limit.
Critical
17