Owner's Manual
26 Dell EqualLogic Storage Management Pack Suite Operations
Rules
There are 28 rules, which process SNMP traps from the EqualLogic device
and display them as Dell EqualLogic Alerts in the SCOM Alerts view.
Table 2-4 lists the Dell EqualLogic Alerts.
Table 2-4. List of Dell EqualLogic Alerts
Alert Description Severity
Dell EqualLogic:
Temperature Sensor
High Threshold Alert
High Threshold Enclosure
Temperature sensor
<temperature sensor name> is
at <value> degrees C.
Temperature sensor is now in
<status> state.
Based on current state of
temperature threshold
Dell EqualLogic:
Temperature Sensor
Low Threshold Alert
Low Threshold Enclosure
Temperature sensor
<temperature sensor name> is
at <value> degrees C.
Temperature sensor is now in
<status> state.
Based on current state of
temperature threshold
Dell EqualLogic: Fan
Speed High Threshold
Alert
Speed of enclosure fan (fan
name) is <speed> rpm. Sensor
is now in <status> state.
Based on current state of
fan speed threshold
Dell EqualLogic: Fan
Speed Low Threshold
Alert
Speed of enclosure fan (fan
name) is <speed> rpm. Sensor
is now in <status> state.
Based on current state of
fan speed threshold
Dell EqualLogic:
Power Supply Fan
Status Alert
Status of Power Supply Fan
<power supply> has changed
to <status>.
Based on power supply fan
health
Dell EqualLogic:
Power Supply Status
Alert
Status of Power Supply module
<power supply> has changed
to <status>.
Based on power supply
health
Dell EqualLogic: RAID
Set Double Faulted
Alert
Double fault has been detected
in the RAID set. User
intervention is required
Critical
A5_bk0.book Page 26 Monday, September 26, 2011 4:40 PM