Table 3-3. List of Supported EqualLogic SNMP Hardware Alerts
Alert Name Description Severity
Dell EqualLogic : Temperature
sensor high threshold exceeded
The temperature
sensor(<sensor>) has exceeded
the high threshold.
Temperature Value =
<temperature> degrees C
2 (Critical)
Dell EqualLogic : Temperature
sensor low threshold exceeded
The temperature
sensor(<sensor>) has exceeded
the low threshold. Temperature
Value = <temperature>
degrees C
2 (Critical)
Dell EqualLogic : Fan Speed
high threshold exceeded
The fan(<fan name>) speed
has exceeded the high
threshold. Fan Speed =
<speed> rpm
2 (Critical)
Dell EqualLogic : Fan Speed low
threshold exceeded
The fan(<fan name>) speed
has exceeded the low threshold.
Fan Speed = <speed> rpm
2 (Critical)
Dell EqualLogic : Power Supply
fan failure
The Power Supply module
(<power supply module
name>) fan has failed.
2 (Critical)
Dell EqualLogic : Power Supply
failure
The Power Supply module
(<power supply module
name>) has detected a failure.
2 (Critical)
Dell EqualLogic : RAID set
double faulted
The RAID set has been detected
to have double faulted
1 (Warning)
Dell EqualLogic : Both Fan
Trays removed
Both Fan Trays of the member
has been removed from the
chassis.
2 (Critical)
Dell EqualLogic : RAID Lost
Cache
RAID driver is unable to recover
the battery-backed cache
2 (Critical)
Dell EqualLogic : One Fan tray
removed
One Fan tray of the member has
been removed from the chassis.
1 (Warning)