20 Version 1.1.0
Property Name
Type
Requirement
Additional Requirement
PartNumber
string
Mandatory
The property shall represent the part number of the
FRU. If the part number is not available, the value shall
be set to NULL.
SerialNumber
string
Mandatory
The property shall represent the serial number of the
FRU. If the serial number is not available, the value
shall be set to NULL.
Tag
string
Mandatory
This property shall be the key and shall have unique
value.
Version
string
Mandatory
The property shall represent the version of the FRU. If
the version is not available, the value shall be set to
NULL.
7.9 DCIM_Slot
403
This section describes the implementation for the DCIM_Slot class. This class provides overall picture of
404
the system hardware where devices can be added or removed.
405
This class is instantiated in the Implementation Namespace.
406
7.9.1 Resource URIs for WinRM®
407
The class Resource URI is
408
“http://schemas.dell.com/wbem/wscim/1/cim-schema/2/DCIM_Slot?__cimnamespace=root/dcim”
409
The key property is the CreationClassName and Tag.
410
The instance Resource URI for DCIM_Slot instance is:
411
“http://schemas.dell.com/wbem/wscim/1/cim-schema/2/DCIM_
412
Slot?__cimnamespace=root/dcim+CreationClassName=DCIM_Slot+Tag=<Tag>”
413
7.9.2 Operations
414
The following table details the implemented operations on DCIM_Slot.
415
Table 19 – DCIM_Slot - Operations
416
Operation Name
Requirements
Required Input
Get
Mandatory
Instance Resource URI
Enumerate
Mandatory
Class Resource URI
417
7.9.3 Properties
418
The table lists the implemented properties for DCIM_Slot instance in a system. The “Type” column shall
419
denote the corresponding property type. The “Requirements” column shall denote whether the property is
420
implemented (for requirement definitions, see section 3). The “Additional Requirement” column shall
421
denote either possible values for the property, or requirements on the value formulation
422